Self Testing

Home

Test Site

Hotel

Corporation

Mass Screening
Features
Non-Invasive
Simple to use
No prescription needed
Rapid, get result in 15 minutes
Stable, with high accuracy
lnexpensive, cost-efficiency
Instructions
01
Wash and dry your hands before removing the package.
02
Place the test card on a flat surface, and remove the adhesive's cover-lay
03
Take out the swabs from stick-end. Then insert the swab fully into the nasal cavity until you feel resistance (about 2-3cm for adults) and gently rotate 5 times for both sides to collect specimens.
04
Insert the swab head into well A from the bottom of well B on the test card.
05
Add 6 drops of the Sample Treatment Solution to well A, then rotate the swab twice from different directions.
06
Fold the left side over to fit two sides together closely, and start timing.
07
Wait for the purple-red line to appear, and read the test results in 15-20 minutes.
08
After testing, put the test card, swab, and sample treatment solution bottle into outer package and seal it tightly. Dispose them in medical waste container according to local laws and regulations.
Result Interpretation
Positive: When a purple-red band appears in the Control Line (C) and Test Line (T).
Negative: When only the Control Line (C) shows a purple-red band and there is no purple-red band appearing in the Test Line (T).
Invalid: If there is no purple-red band appearing in the Control Line (C), regardless of the result shown in the Test Line (T), it indicates either the operation process is incorrect or the test kit has been damaged. In this case, please retest with a new test kit strictly following the instruction. If the problem reoccurs, please report it to your local supplier.
LEPU Profile
Lepu Medical Technology ( Beijing ) Co., Ltd was established in 1999. It is specialized in developing, manufacturing and marketing high-tech medical devices and equipment. Today, Lepu Medical has grown into a global leading medical technology company in the fields of cardiovascular interventions, structural heart diseases, cardiac rhythm management, anesthesia and critical care, in vitro diagnostics and general surgery with products include coronary stents, dilatation balloon catheters, interventional accessories, occlusion devices, mechanical heart valves, electrophysiology catheters, pacemakers, in vitro diagnostic equipment and biomarkers, DSA systems and surgical staplers. In 2009 Lepu Medical successfully went public, and was listed on Chinext Shenzhen StockExchange Market ( stock code: 300003).
Global Market
FAQ
A.
This product (SARS-CoV-2 Antigen Rapid Test Kits for Self-testing) is intended for use as an aid in the diagnosis of SARS-CoV-2 infection for individuals with symptoms or other epidemiological reasons to suspect a COVID-19 infection, including both adults and children. In the case of children, samples must be collected by an adult following our illustrated step-by-step guide.
A.
While both types of Lepu’s SARS-CoV-2 test kits offer rapid antigen testing based on the colloidal gold immunochromatographical technology, the self-testing version is designed to serve the needs of consumers who prefer to perform rapid antigen testing in a home setting and is made available for purchase over the counter, whereas non-self-testing version is designed for medical specialists to use in a clinical setting.
A.
All authentic Lepu self-testing kits carry a light-blue label with miniature Lepu logo, anti-counterfeiting shading, regiment floral pattern, gilding, and temperature-sensitive ink used for fire discoloration. By scratching the covered bottom part of the label, you will find a unique code used for our online authenticity check-up system (https://en.lepumedical.com/).
A.
You will first perform lower nostril nasal swab (2~3cm) in both nasal cavities. Then, you will insert your swab with sample into the testing card, add sample treatment solution to it, and then rotate the swab until fully mixed. The result will come out after 15~20 minutes. A more detailed instruction can be found on the illustrated instruction card included in your package.
A.
The result window consists of a “control” line and a “test” line. When both lines turn purple-red, however faint the color on the “test” line is, it is a positive result, which means you may have COVID-19. When only the “control” line turns purple-red, it is a negative result, which means SAR-CoV-2 was not found in this sample. If the “control” line shows no color or blue color, it is an invalid result, which means either the operation process is incorrectly done or the test paper has been damaged. If you have trouble determining the test result, please refer to the illustrations on your instruction card.
A.
After tested positive, you should inform your health care provider of the result. Your healthcare provider will work with you to further confirm the diagnosis of COVID-19 and determine how best to care for you. You should also continue following the public health protocol in place in your local area. In general, it is advised that one should abstain from visiting public space and only leave home to obtain necessary medical care.
A.
False negative results could be due to various reasons, including but not limited to: (1) the level of antigen in the sample is below the detection limit of the test; (2) a specimen is improperly collected or handled; (3) inadequate or excessive amount of sample treatment solution is used; (4) swabs are not twirled properly within the test card; (5) test card is moved or disturbed in the waiting process; (6) test result is read before 15 minutes; (7) the tested individual has more than seven days of symptoms; (8) the tested individual is taking mupirocin.
A.
The test kit is valid for 18 months when stored in a dry and dark place with temperature of 4-30℃ and humidity of less than 70%. The test card must be used within one hour after it is taken out from the aluminum foil bag. The sample treatment solution should be used immediately after opening. Please consult package label for dates of manufacture and expiration.
A.
Please dispose of all used specimens, test cards, and other waste in accordance with relevant local laws and regulations. The box and instruction card may be recycled if they have not been contaminated.